Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Photodiagnosis Photodyn Ther ; 44: 103794, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37699468

RESUMO

BACKGROUND: The effectiveness of in-office bleaching protocols performed with violet LED light either combined with a bleaching agent containing 37% carbamide peroxide, or not, was determined by comparing teeth with different degrees of darkening. METHODOLOGY: Eighty bovine incisors were separated into groups of "light" teeth (luminosity greater than or equal to B3) and "dark" teeth (less than or equal to A3.5) to receive the protocols: HP - 35% hydrogen peroxide (Whiteness HP), CP - 37% carbamide peroxide (Whiteness SuperEndo), LED - violet LED light (Bright Max Whitening), CPLED - CP associated with the LED. For color analysis the CIEL*a*b* e WID, ΔEab, ΔE00 e ΔWID parameters were used. Data were analyzed using Mann-Whitney, Kruskal-Wallis, Dunn, Friedman or Nemenyi tests (α = 5%). RESULTS: HP and CP resulted in similar color change values (ΔEab, ΔE00 e ΔWID) for light and dark teeth (p > 0.05). Dark teeth showed better bleaching effectiveness (ΔEab, ΔE00 e ΔWID) than light teeth when CPLED was used (p < 0.05). LED showed color change that were below the limits of acceptability and perceptibility for ΔWID. CONCLUSION: light teeth are effectively bleached with the use of HP or CP, whereas dark teeth respond better to treatment with the CPLED protocol. Violet LED used alone did not show a satisfactory result.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida/farmacologia , Clareamento Dental/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Incisivo , Cor
2.
Photodiagnosis Photodyn Ther ; 44: 103762, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37640206

RESUMO

BACKGROUND: The effectiveness of dental color change was assessed by incorporating titanium dioxide (TiO2) into 37% carbamide peroxide bleaching agent associated with hybrid light. METHODOLOGY: Fifty bovine incisors were selected to receive the bleaching treatment, and separated into five groups (n = 10): 35% hydrogen peroxide (HP) (Whiteness HP, FGM/HP); 37% carbamide peroxide (CP) (Whiteness SuperEndo, FGM/CP); CP + hybrid light (HL) (CP HL); CP + 1% TiO2 (CP TiO2); CP TiO2 + hybrid light (CP TiO2 HL). The bleaching gels were applied to the dental surface for 30 min. Hybrid light (Whitening Plus, DMC/infrared laser diodes + blue LEDs +violet LEDs) was applied with 1 min of active light, alternating with 1 min of pause. A spectrophotometer (VITA Easyshade® Advance, Vita) was used to determine the color of the dental elements at baseline and time points after the 1st, 2nd and 3rd bleaching sessions. Color change effectiveness was evaluated using Vita Classical, CIEL*a*b*, WID and ΔEab, ΔE00 and ΔWID parameters. RESULTS: Generalized mixed linear models for repeated measures (α = 5%) showed significant decrease in Vita Classical scores and a* and b* values, as well as an increase in L* and ∆WID values for all the groups. Higher color change values for ΔEab were observed for CP HL and CP TiO2 HL, while those of ΔE00 and ΔWID were higher for CP TiO2 HL at the end of the bleaching treatment. CONCLUSION: Hybrid light applied with TiO2 incorporated into CP potentiated the effectiveness of the color change in the tooth structure.


Assuntos
Clareadores , Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida/farmacologia , Clareadores Dentários/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Peróxido de Hidrogênio/farmacologia , Ácido Hipocloroso , Incisivo , Cor
3.
J Mech Behav Biomed Mater ; 144: 105961, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37320893

RESUMO

AIMS: To evaluate the influence of the type of preparation and mechanical cycling on the fracture load and failure mode of semi-direct posterior resin composite restorations. METHODS: In total, 70 healthy third molars were used; 10 belonging to the control group (C - unprepared teeth) and 60 teeth prepared and restored with nanoparticle resin composite, divided into 3 groups (n = 20): O - exclusively occlusal preparation (Table Top); OV - occlusal preparation with buccal extension (Veneerlay); OVP - Occlusal preparation with chamfer on the proximal and buccal-lingual/palatal surfaces (Overlay). The preparations were performed with diamond burs with a thickness of 1 mm. The restorations were made with nanoparticulate resin composite (Filtek Z350 XT) and subsequently received additional polymerization (thermoprocessing). Cementation was performed with the use of universal adhesive system (Single Bond Universal) on dental substrate and dual resin cement (RelyX ARC). Half of the teeth in each group (n = 10) were submitted to mechanical cycling, simulating 6 months of clinical service (5 × 105 fatigue cycles), under dynamic loading of 130 N, at a frequency of 2Hz. Fracture load tests were performed in a universal testing machine with a 200 kgf load cell. Failure mode was classified using scores. Generalized linear models and Fisher Exact tests were applied to the data (significance level of 5%). RESULTS: There were no significant differences between the types of preparation (p = 0.9435), or relative to cycling (p = 0.3764). The Fisher Exact Test showed a significant association between the groups and the type of failure (p = 0.0006), with preparations O (with cycling) and OVP (with and without cycling) exhibiting most failures with restoration fractures without involvement of the dental remnant. CONCLUSIONS: Semi-direct restorations showed resistance to fracture load similar to that of healthy teeth and were capable of withstanding functional masticatory loads. The type of preparation influenced the failure mode of teeth. The Table Top and Overlay types of preparations were those had fewer catastrophic failures, suggesting that since they are more conservative preparations, they made it possible for the tooth to receive a new restorative procedure in the future in cases of failures.


Assuntos
Resinas Compostas , Cimentos de Resina , Teste de Materiais , Resinas Compostas/química , Cimentos de Resina/química , Desenho Assistido por Computador , Análise do Estresse Dentário , Falha de Restauração Dentária , Restauração Dentária Permanente , Porcelana Dentária
4.
J Clin Exp Dent ; 15(5): e403-e410, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37214755

RESUMO

Background: Greater degradation of the hybrid layer is expected when a universal adhesive system is used, especially in the conventional application strategy. Therefore, it would important to evaluate the effect of the ethanol (ETH) and a potential matrix protease inhibitor (caffeic acid phenethyl ester/ CAPE) to maximize the ability to achieve stable dentin bond strength. The aim of this study was to evaluated the effect of ETH on a wet-bonding technique, and dentin pretreatments with different concentrations of CAPE in ethanolic solution, followed by application of a universal adhesive system (Single Bond Universal) to inhibit proteolytic activity. Material and Methods: Dentin blocks were allocated to eight experimental groups according to the strategy (total-etch our self-etch) and treatments: ETH, or dentin pretreatment with CAPE (at 0.5%, 2.5%; and 5.0%). Half of each block (each hemiblock) served as the control (without dentin pretreatments) for the same group. The bonding strategy was performed (adhesive system/ restoration with composite resin). Two slices were obtained from each hemiblock and evaluated using in situ zymography. The proteolytic activity was analyzed by quantifying the green photons of the images obtained under a fluorescence microscope in three dentin locations close to the dentin-resin interface: hybrid layer (HL), underlying dentin (UD) and deep dentin (DD). Results: Wilcoxon tests (for comparison between experimental and control groups) and Friedman and Nemenyi tests (for comparisons between interface locations) showed that there was no difference between the groups with different CAPE concentrations and the respective control groups (p>0.05). ETH reduced the proteolytic activity at the HL and UD (p<0.05). Conclusions: The wet-bonding technique with ETH proved effective in reducing the proteolytic activity. The use of CAPE in different concentrations solubilized in ethanol did not have a favorable effect on proteolytic inhibition. Key words:Adhesives, Hybrid layer, Dentin, Metalloproteinases.

5.
Braz Oral Res ; 37: e047, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255067

RESUMO

To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Animais , Bovinos , Materiais Dentários , Análise de Elementos Finitos , Coroas , Vidro , Análise do Estresse Dentário , Resinas Compostas
6.
Braz Oral Res ; 37: e052, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255072

RESUMO

This study aimed to evaluate the effect of endodontic sealer (ES) on bond strength (BS) of prefabricated or milled-CAD-CAM (computer-aided design and computer-aided manufacturing) glass-fiber-posts (GFP). Canals of 90 single-rooted teeth were prepared for filling by the single-cone technique with gutta-percha and one of the following ES: AH Plus (epoxy resin), Endofill (zinc-oxide and eugenol), and Bio-C Sealer (calcium-silicate). After post-space preparation, tooth-specimens were equally divided in half according to type of GFP to be used. In the half to receive milled-CAD-CAM posts, tooth specimens were molded with acrylic resin to obtain replicas. These were scanned to enable the laboratory to produce the milled-CAD-CAM GFPs (Fiber CAD Lab, Angelus) by the subtractive technique. The other half of samples received prefabricated GFPs (Exacto, Angelus) (n=15). The GFPs were cemented with dual-cure resin cement (Panavia F2.0, Kuraray). Each root was sectioned into two slices per root region (cervical, middle, apical) that were subjected to the push-out BS test, in a universal testing machine. Failure mode (FM) was classified by scores. The BS data were submitted to generalized linear model analyses, while FM was analyzed using the chi-square test (a=0.05). BS showed no significant difference among the three ES (p > 0.05). BS was significantly higher for prefabricated (mean 10.84 MPa) versus milled-CAD-CAM GFPs (mean 6.94 MPa) (p <0.0001), irrespective of ES. The majority showed mixed failures. It could be concluded that type of ES did not affect BS of GFPs to dentin, and prefabricated-GFPs had higher bond-strength than customized-milled-CAD-CAM GFPs.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular , Teste de Materiais , Análise do Estresse Dentário , Materiais Restauradores do Canal Radicular/química , Vidro , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Desenho Assistido por Computador , Dentina
7.
Photodiagnosis Photodyn Ther ; 42: 103631, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37236518

RESUMO

BACKGROUND: Dental color change and the temperature of the pulp chamber and of the buccal surface were evaluated during bleaching with 37% carbamide peroxide (CP) with continuous vs fractionated violet LED light protocols. METHODOLOGY: Bovine incisors received in-office bleaching for 30 min using different light protocols (Bright Max Whitening, MMOptics). Teeth were separated into groups (n = 10): HP) 35% hydrogen peroxide (Whiteness HP, FGM)/no light; CP) 37% carbamide peroxide (Whiteness SuperEndo, FGM)/no light; CP10) CP+10 min of continuous light; CP20) CP+20 min of continuous light; CP30) CP+30 min of continuous light; CPF) CP+20 cycles of 60 s light / 30 s no light (fractionated). Color evaluations were performed at different times. Evaluations of pulp and buccal surface temperatures were performed before and throughout the 30 min of bleaching. RESULTS: Generalized linear models for repeated measures over time were applied to the data (α=5%). After the 1st session, CP20 and CP30 had significantly lower b* values ​​than CP and CP10 (p = 0.0071). For ΔEab and ΔE00, CPF, CP20 and CP30 showed the highest color change among the treatments after the third bleaching (p<0.05). For temperature evaluations, CP30 showed higher pulp and buccal surface temperatures than the other protocols (p<0.0001) after 20 min. CONCLUSION: Fractionated or continuous application of violet LED for 20 or 30 min leads to greater effectiveness of color change. All protocols with the application of LED led to an increase in pulp and buccal surface temperatures during bleaching, although the fractionated application appeared to be safer than the use of continuous light.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida , Clareamento Dental/métodos , Temperatura , Polpa Dentária , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Cor
8.
Rev Bras Ginecol Obstet ; 45(3): 134-141, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37105197

RESUMO

OBJECTIVE: This study assessed maternal mortality (MM) and related factors in a large-sized municipality in the Southeastern region of Brazil (Campinas, São Paulo) during the period 2000-2015. METHODS: This study consisted of two phases: 1. An analytical nested case-control phase that assessed the impact of individual and contextual variables on MM; and 2. an ecological phase designed to contextualize maternal deaths by means of spatial analysis. The case group consisted of all maternal deaths (n = 87) and the control group consisted of 348 women who gave birth during the same period. Data analysis included descriptive statistics, association, and multiple logistic regression (MLR) tests at p < 0.05 as well as spatial analysis. RESULTS: Maternal Mortality Ratio was 37 deaths per 100.000 live births. Deaths were dispersed throughout the urban territory and no formation of cluster was observed. MLR showed that pregnant women aged ≥ 35 years old (OR = 2.63) or those with cesarean delivery (OR = 2.51) were more prone to maternal death. CONCLUSION: Maternal deaths were distributed dispersedly among the different socioeconomic levels and more prone to occur among older women or those undergoing cesarean deliveries.


OBJETIVO: Esse estudo avaliou a mortalidade materna (MM) e fatores relacionados em um município de grande porte da região sudeste do Brasil (Campinas, São Paulo) no período de 2000-2015. MéTODOS:: Esse estudo consistiu de duas fases: 1. Uma fase analítica de caso-controle que avaliou o impacto de variáveis individuais e contextuais na MM; 2. Uma fase ecológica delineada para contextualizar as mortes maternas por meio de análise espacial. O grupo caso consistiu de 87 mortes maternas e o grupo controle de 348 mulheres que tiveram bebês durante o mesmo período. Os dados foram analisados por estatística descritiva, testes de associação e regressão logística múltipla (RLM) (p < 0,05) assim como análise espacial. RESULTADOS: A taxa de mortalidade materna foi de 37 mortes para cada 100.000 nascidos vivos. As mortes foram dispersas por todo o território urbano e não se observou formação de clusters. Na RLM observou-se que mulheres grávidas com idade ≥ 35 anos (OR = 2,63) ou aquelas que passaram por cesárea (OR = 2,51) foram mais propensas à morte materna. CONCLUSãO:: As mortes maternas foram distribuídas dispersamente entre os diferentes níveis socioeconômicos e mais propensas a ocorrer entre mulheres ≥ 35 anos de idade ou que passaram por cesárea.


Assuntos
Parto Obstétrico , Morte Materna , Mortalidade Materna , Adulto , Idoso , Feminino , Humanos , Gravidez , Brasil/epidemiologia , Cesárea , Idade Materna , Parto , Parto Obstétrico/métodos , Estudos de Casos e Controles
9.
Clin Oral Investig ; 27(7): 3545-3556, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36995429

RESUMO

OBJECTIVES: To evaluate the effect of acid erosion on different physical properties of resin composite with S-PRG (surface pre-reacted glass) fillers, by conducting simulations of intrinsic and extrinsic sources. MATERIALS AND METHODS: Cylindrical samples (Ø6 vs. 2 mm) of a conventional nanohybrid resin composite (Forma, Ultradent) and of a nanohybrid resin composite with S-PRG filler (Beautifil II, Shofu) were exposed to erosive cycling (5 days), based on (n=12) remineralizing solution (control); 0.3% citric acid (pH=2.6); or 0.01 M hydrochloric acid (pH=2). Roughness (Ra), microhardness (KHN), and color (CIEL*a*b*, CIEDE2000, and Vita scale (SGU)) factors were analyzed at the initial and final time points, and the general color changes (ΔEab, ΔE00, ΔSGU) were calculated. Final images were obtained using scanning electron microscopy (SEM). The data were evaluated by generalized models, Mann-Whitney, Wilcoxon, Kruskal-Wallis, and Dunn tests (α=0.05). RESULTS: Regarding KHN, there was no difference between the groups or the time periods (p = 0.74). As for Ra, there was a significant increase in the Ra of both composites after cycling with hydrochloric acid, but only the resin composite with S-PRG filler showed a change in Ra after cycling with citric acid (p = 0.003). After cycling with citric and hydrochloric acid, the highest Ra values were found for the resin composite with S-PRG filler (p < 0.0001), corroborating the result of images (SEM) indicating loss of filler and porosities in this material. The resin composite with S-PRG filler showed higher ΔEab and ΔE00, in addition to more negative ΔSGU values and lower L* values after exposure to both acids, compared to the control (p < 0.05). CONCLUSION: The acidic conditions altered the roughness and color stability of the materials tested, pointing out that the resin composite containing S-PRG filler showed greater degradation of its physical properties than the conventional resin composite. CLINICAL RELEVANCE: Bioactive materials are relevant, considering that their properties interact with dental hard tissues; however, the S-PRG-based resin composite showed greater degradation under acidic conditions than the conventional resin composite.


Assuntos
Resinas Compostas , Ácido Clorídrico , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Teste de Materiais , Cor
10.
Rev. bras. ginecol. obstet ; 45(3): 134-141, Mar. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449715

RESUMO

Abstract Objective: This study assessed maternal mortality (MM) and related factors in a large-sized municipality in the Southeastern region of Brazil (Campinas, São Paulo) during the period 2000-2015. Methods: This study consisted of two phases: 1. An analytical nested case-control phase that assessed the impact of individual and contextual variables on MM; and 2. an ecological phase designed to contextualize maternal deaths by means of spatial analysis. The case group consisted of all maternal deaths (n = 87) and the control group consisted of 348 women who gave birth during the same period. Data analysis included descriptive statistics, association, and multiple logistic regression (MLR) tests at p < 0.05 as well as spatial analysis. Results: Maternal Mortality Ratio was 37 deaths per 100.000 live births. Deaths were dispersed throughout the urban territory and no formation of cluster was observed. MLR showed that pregnant women aged > 35 years old (OR = 2.63) or those with cesarean delivery (OR = 2.51) were more prone to maternal death. Conclusion: Maternal deaths were distributed dispersedly among the different socioeconomic levels and more prone to occur among older women or those undergoing cesarean deliveries.


Resumo Objetivo: Esse estudo avaliou a mortalidade materna (MM) e fatores relacionados em um município de grande porte da região sudeste do Brasil (Campinas, São Paulo) no período de 2000-2015. Métodos: Esse estudo consistiu de duas fases: 1. Uma fase analítica de caso-controle que avaliou o impacto de variáveis individuais e contextuais na MM; 2. Uma fase ecológica delineada para contextualizar as mortes maternas por meio de análise espacial. O grupo caso consistiu de 87 mortes maternas e o grupo controle de 348 mulheres que tiveram bebês durante o mesmo período. Os dados foram analisados por estatística descritiva, testes de associação e regressão logística múltipla (RLM) (p < 0,05) assim como análise espacial. Resultados: A taxa de mortalidade materna foi de 37 mortes para cada 100.000 nascidos vivos. As mortes foram dispersas por todo o território urbano e não se observou formação de clusters. Na RLM observou-se que mulheres grávidas com idade > 35 anos (OR = 2,63) ou aquelas que passaram por cesárea (OR = 2,51) foram mais propensas à morte materna. Conclusão: As mortes maternas foram distribuídas dispersamente entre os diferentes níveis socioeconômicos e mais propensas a ocorrer entre mulheres > 35 anos de idade ou que passaram por cesárea.


Assuntos
Humanos , Feminino , Gravidez , Fatores Socioeconômicos , Mortalidade Materna , Fatores de Risco , Estudo Observacional
11.
J Esthet Restor Dent ; 35(4): 677-686, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36602235

RESUMO

OBJETIVE: This study evaluated the influence of alveolar bone height and post type on compressive force resistance, fracture pattern, and stress distribution in endodontically treated teeth. MATERIALS AND METHODS: Bovine roots were endodontically treated and divided into eight groups (n = 10) according to alveolar bone height (normal alveolar bone and alveolar bone loss - 2 and 5 mm from the margin of the crown, respectively) and post type (prefabricated glass fiber post, anatomic glass fiber post, customized milled glass fiber post-and-core and customized milled polyetheretherketone (PEEK) post-and-core). Mechanical fatigue was simulated (300.000 cycles/50 N/1.2 Hz). Compression force resistance (N) was analyzed by two-way ANOVA and Tukey test (α = 0.05). Fracture patterns were described as percentages. Stress distribution was analyzed by finite element analysis. RESULTS: Significant diferences were found for alveolar bone height (P < 0.0001): normal alveolar bone groups showed higher mean values of compression force resistance compared to alveolar bone loss groups, while no significant differences were found for post type (P = 0.4551), and there was no double interaction between them (P = 0.5837). Reparable fractures were more predominant in normal alveolar bone groups, especially in the milled glass fiber and PEEK post-and-core groups. Stress distribution was similar in groups with prefabricated glass fiber posts and milled PEEK posts-and-cores, and the alveolar bone loss condition significantly increased stress concentration and strain values, mainly on apical dentin. CONCLUSIONS: Alveolar bone loss due to physiological aging and/or periodontal disease may lead to increased risk of restored tooth failure, although milled glass fiber and PEEK posts-and-cores provide more reparable fractures. CLINICAL SIGNIFICANCE: Custom-made glass fiber and PEEK post-and-cores are interesting options, since they enable clinicians to work with a single-body post-and-core system that avoid several materials interfaces and fits well in the root canal provided promising results to improve the failure behavior of restored roots, as they offer more reparable fractures even in situations of alveolar bone loss.


Assuntos
Perda do Osso Alveolar , Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Animais , Bovinos , Materiais Dentários , Fraturas dos Dentes/prevenção & controle
12.
Clin Oral Investig ; 27(4): 1745-1755, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36441269

RESUMO

OBJECTIVES: The effects of different concentrations of titanium dioxide (TiO2) into 40% hydrogen peroxide (HP) were evaluated as regards the effectiveness of dental color change either associated with activation by polywave LED light or not. MATERIALS AND METHODS: TiO2 (0, 1, 5, or 10%) was incorporated into HP to be applied during in-office bleaching (3 sessions/40 min each). Polywave LED light (Valo Corded/Ultradent) was applied or not in activation cycles of 15 s (total time of 2 min). The color of 80 third molars separated into groups according to TiO2 concentration and light activation (n = 10) was evaluated at baseline and at time intervals after the 1st, 2nd, and 3rd bleaching sessions. RESULTS: WID value was significantly higher when using HP with 5% TiO2 in the 2nd session than the values in the other groups (p < 0.05). After the 2nd and 3rd sessions, the ΔEab value was significantly higher when activated with light (p < 0.05) for all agents containing TiO2 or not. Zeta potential and pH of the agents were not modified by incorporating TiO2 at the different concentrations. CONCLUSIONS: The 5% TiO2 in the bleaching agent could enhance tooth bleaching, even without light application. Association with polywave LED light potentiated the color change, irrespective of the presence of TiO2 in the bleaching gel. CLINICAL SIGNIFICANCE: HP with 5% TiO2 could lead to a greater tooth bleaching response in the 2nd clinical session, as well as the polywave light can enhance color change.


Assuntos
Clareadores , Nanotubos , Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/farmacologia , Clareadores Dentários/farmacologia
13.
Photodiagnosis Photodyn Ther ; 41: 103254, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36572111

RESUMO

BACKGROUND: The purpose of this study was: 1) to analyze the physical-chemical properties of hydrogen peroxide (HP) agents at 7.5% (HP7) and 35% (HP35), and the association with or without TiO2 nanotubes; 2) to evaluate dental bleaching effectiveness by using HP7 and HP35 together with or without TiO2 nanotubes, and applied with or without violet LED (VL). METHODOLOGY: 80 bovine incisors were treated according to groups (n = 10): HP35; HP35 + VL; HP35T (HP35 + TiO2); HP35T + VL; HP7; HP7 + VL; HP7T (HP7 + TiO2); HP7T + VL. Bleaching effectiveness was measured at 4 time points according to the Vita Classical, CIEL*a*b*, CIEDE2000, and WID parameters. HP35, HP35T, HP7, and HP7T were evaluated for mass change, pH, mean particle size (P), polydispersity (PDI), and zeta potential (ZP), over 6 months of storage. RESULTS: The pH of HP35 thickener was higher when associated to TiO2. At baseline, both of the bleaching gels containing TiO2 had lower P, PDI, and PZ (p < 0.05). All groups showed a significant decrease in Vita Classical color scores (p = 0.0037). There was a higher L* value, and lower b* values for HP7 when associated to VL after the 3rd session. (p < 0.05). HP35T showed higher color change (ΔEab, ΔE00), and lower a* value in the presence of VL (p < 0.05). ΔWID presented lower values for both gels, when TiO2 was incorporated (p ≤ 0.05). CONCLUSION: The incorporation of TiO2 to the bleaching gel showed good stability with minimal variations in physical-chemical properties. The color change in HP35 was more effective than in HP7, but the VL boosted the bleaching effectiveness of HP7, whereas TiO2 did not increase bleaching effectiveness.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Hidrogênio , Clareadores Dentários/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Géis , Ácido Hipocloroso , Cor
14.
Braz. oral res. (Online) ; 37: e047, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439732

RESUMO

Abstract To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.

15.
Braz. oral res. (Online) ; 37: e052, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439734

RESUMO

Abstract This study aimed to evaluate the effect of endodontic sealer (ES) on bond strength (BS) of prefabricated or milled-CAD-CAM (computer-aided design and computer-aided manufacturing) glass-fiber-posts (GFP). Canals of 90 single-rooted teeth were prepared for filling by the single-cone technique with gutta-percha and one of the following ES: AH Plus (epoxy resin), Endofill (zinc-oxide and eugenol), and Bio-C Sealer (calcium-silicate). After post-space preparation, tooth-specimens were equally divided in half according to type of GFP to be used. In the half to receive milled-CAD-CAM posts, tooth specimens were molded with acrylic resin to obtain replicas. These were scanned to enable the laboratory to produce the milled-CAD-CAM GFPs (Fiber CAD Lab, Angelus) by the subtractive technique. The other half of samples received prefabricated GFPs (Exacto, Angelus) (n=15). The GFPs were cemented with dual-cure resin cement (Panavia F2.0, Kuraray). Each root was sectioned into two slices per root region (cervical, middle, apical) that were subjected to the push-out BS test, in a universal testing machine. Failure mode (FM) was classified by scores. The BS data were submitted to generalized linear model analyses, while FM was analyzed using the chi-square test (a=0.05). BS showed no significant difference among the three ES (p > 0.05). BS was significantly higher for prefabricated (mean 10.84 MPa) versus milled-CAD-CAM GFPs (mean 6.94 MPa) (p <0.0001), irrespective of ES. The majority showed mixed failures. It could be concluded that type of ES did not affect BS of GFPs to dentin, and prefabricated-GFPs had higher bond-strength than customized-milled-CAD-CAM GFPs.

16.
Braz. j. oral sci ; 22: e237545, Jan.-Dec. 2023. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1433748

RESUMO

Aim: To evaluate dentin permeability after pretreatment with 2.5% aqueous solution of titanium tetrafluoride (TiF4), followed by a self-etching universal adhesive system. Methods: Forty dentin discs (1.5 mm thick) were randomly divided into groups according to the application or non-application of a pretreatment, and the type of adhesive system to be tested (two-step self-etching/ Clearfil SE Bond/ Kuraray Medical, or universal adhesive system/ Single Bond Universal/ 3M ESPE). Both sides of the discs were conditioned with 37% phosphoric acid to remove the smear layer. The first hydraulic conductivity measurement (L1) was performed in a permeability machine, under 5 PSI pressure. The samples were sanded again to form a standardized smear layer. The teeth designated for pre-treatment with TiF4 received the TiF4 solutions applied actively for 60 seconds, and the adhesive systems were applied according to the manufacturer's instructions. Then, a new hydraulic conductivity measurement (L2) was performed for the purpose of calculating the hydraulic conductance at a later time, considering the water viscosity and the thickness of the specimen. The percentage (L) of dentin permeability after application of the adhesive system was obtained (L (%) = [(L1-L2) x100] / L1). The Mann-Whitney non-parametric test was applied. Results: There was no difference between the two adhesive systems, or between the groups with or without pretreatment, as regards dentin permeability (p>0.05). Conclusion: Pretreatment with 2.5% TiF4 did not influence dentin permeability, irrespective of the adhesive system used


Assuntos
Titânio , Adesivos Dentinários , Permeabilidade da Dentina , Fluoretos
17.
Braz. j. oral sci ; 21: e228852, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1392917

RESUMO

Aim: To evaluate the occlusal and internal marginal adaptation of inlay restorations made of different materials, using CAD-CAM. Methods: Preparations were made for MOD inlays of one-third intercuspal width and 4 mm depth in 30 third human molars. The teeth were restored using CAD-CAM materials (n=10) of nanoceramic resin (Lava Ultimate), polymer-infiltrated ceramic network (VITA ENAMIC), or lithium disilicate glass-ceramic (IPS e.max CAD). The specimens were cemented with dual resin cement and sectioned at the center of the restoration, after which the two halves were evaluated, and photographed The occlusal and internal discrepancy (µm) was determined at five points: cavosurface angle of the occlusal-facial wall (CA-O); center of the facial wall (FW); faciopulpal angle (FPA); center of the pulpal wall (PW); and center of the lingual wall (LW). The data were submitted to the Kruskal-Wallis and the Dunn tests (α=0.05). Results: No difference was observed among the materials regarding the occlusal discrepancy at the CA-O, FPA, or PW internal points. The e.max CAD measurement at FW showed larger internal discrepancy than that of Lava (p=0.02). The internal discrepancy at LW was greater for e.max CAD than VITA ENAMIC (p=0.02). Conclusion: Lithium disilicate glass-ceramic presented greater internal discrepancy in relation to the surrounding walls of the inlay preparations


Assuntos
Cerâmica , Desenho Assistido por Computador , Adaptação Marginal Dentária , Materiais Dentários , Restaurações Intracoronárias
18.
Materials (Basel) ; 15(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35955276

RESUMO

This study aimed to evaluate the influence of thermomechanical cycling (TMC) and type of abutment on the misfit and compressive strength of the implant−abutment interface. Forty 3.75-mm external hexagon implants with 25° angled abutments were divided into four groups (N = 10). Group A: overcast plus TMC; Group B: overcast without TMC; Group C: completely cast plus TMC; Group D: completely cast without TMC. Abutments were fixed to the implants with 32-Ncm torque, and groups A and C specimens were cyclically loaded at 80 N with 2 Hz for 1 million cycles. The misfit on the implant−abutment interface was evaluated by optical microscope (100×) and the compressive strength test was performed in a universal test machine. For statistical analysis, a two-way ANOVA and post hoc Tukey test were used. There was no difference in misfit presented by all the abutments in the absence of TMC (p > 0.05). When TMC was performed, the completely cast abutments showed greater misfit than overcast ones (p = 0.001). Regarding compressive strength, irrespective of TMC performed, the overcast abutments showed higher compressive strength values than completely cast abutments (p = 0.003). Moreover, disregarding the type of abutment used, the absence of TMC provided higher compressive strength values (p < 0.001). It was concluded that thermomechanical cyclic loading aggravated the misfit, especially in completely cast abutments, regardless of material or fabrication technique, and reduced the compressive strength of the two types of abutments tested.

19.
Am J Dent ; 35(1): 37-42, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35316591

RESUMO

PURPOSE: To evaluate the effect of polishing systems (discs or rubbers) on surface roughness (Ra) and color change (ΔE) of two bulk fill and one conventional resin composite after immersion in a dye solution. METHODS: 180 samples (10 mm x 2 mm) were separated into three groups: (1) Resin composite: Filtek One Bulk Fill (FO), Tetric N-Ceram Bulk Fill (TNC), Filtek Z350 XT (FXT) (n= 60); (2) polishing system: unpolished (control); aluminum oxide discs (Sof-Lex, AOD); cup-shaped abrasive rubber polishers (Astropol, CSA) (n= 20), and (3) immersion solutions: coffee or distilled water (n= 10). Immersion was under 5 mL of each solution for 3 hours daily, for 30 days. Measurement of Ra and ∆E was made considering two times: initial (after polishing) and final (after immersion), in addition to surface analysis by scanning electron microscopy at the end. Kruskal-Wallis, Mann-Whitney, and Dunn (α= 0.05) was used. RESULTS: For the unpolished samples after immersion in coffee, TNC (P= 0.007) showed lower ΔE than FXT and FO. For polished samples with CSA and immersed in coffee, TNC followed by FXT showed lower ΔE than in the absence of polishing. Polishing with AOD and immersed in coffee: FO had smaller ΔE than when not polished. For Ra, TNC and FO had lower values after using AOD, whereas for FXT lower Ra was noted with CSA. CLINICAL SIGNIFICANCE: The roughness and color stability of resin composites are mediated by the polished material, polishing system and dye solution. The best results were found for Tetric N-Ceram polished with aluminum oxide discs.


Assuntos
Óxido de Alumínio , Polimento Dentário , Polimento Dentário/métodos , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
20.
J Adhes Dent ; 24(1): 49-56, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35227046

RESUMO

PURPOSE: To evaluate the influence of dimethyl sulfoxide (DMSO) solutions used as dentin pretreatments on microtensile bond strength (µTBS), as well as the dentin/restoration interface micromorphology of a universal adhesive in etch-and-rinse or self-etch mode. MATERIALS AND METHODS: Eighty blocks of dentin were submitted to acid conditioning with 35% phosphoric acid (etch-and-rinse), or not (self-etch), and distributed among the treatments (n = 10): CON: Scotchbond Universal/3M Oral Care; DMSO: pretreatment with DMSO; DMSO/water: pretreatment with DMSO in water (1:1); DMSO/ethanol: pretreatment with DMSO in ethanol (1:1). Microtensile bond strength and failure tests were performed after 24-h and 6-month storage. The tooth-restoration interface was evaluated using scanning electron microscopy to assess the hybrid layer formed. RESULTS: The interaction between treatments, storage time, and etching modes was not significant for µTBS (p = 0.2469). The DMSO, DMSO/water and DMSO/ethanol pretreatments did not affect µTBS values at either time point (p = 0.8732). Aging decreased µTBS over time only for the etch-and-rinse strategy, although the groups presented higher microtensile bond strengths in etch-and-rinse mode than in self-etch mode at both time points (p < 0.0001). The micromorphological images of the interface showed that different DMSO pretreatment solutions did not impair hybrid layer formation. CONCLUSION: The use of dentin pretreatments containing DMSO did not improve the bonding or the micromorphology of a universal adhesive in etch-and-rinse or self-etch modes.


Assuntos
Colagem Dentária , Adesivos Dentinários , Colagem Dentária/métodos , Cimentos Dentários , Dentina , Adesivos Dentinários/química , Dimetil Sulfóxido/química , Dimetil Sulfóxido/farmacologia , Teste de Materiais , Cimentos de Resina , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...